languageen

Dropped connections and failed handset handovers are typical symptoms of a multi-cell installation with weak DECT sync source RSSI values.

To troubleshoot this, log in to the Web User Interface of each base station of the affected multi-cell and have a look at the DECT Chain and the Base Station Group. Check the DECT Sync Source RSSI values.

Make sure that the "DECT synchronization source" of each base station has an RSSI value of minimum -75dBm. Weaker RSSI values (e.g. -76dBm or less) can cause dropped connections and failing handovers.


Include Page
Howto Footer - uni-en
Howto Footer - uni-en

Content by Label
showLabelsfalse
max20
spacesPW
showSpacefalse
sorttitle
typepage
cqllabel = "dect-multicell" and label in ("m700","troubleshooting") and type = "page"
labelsdect dect-multicell

Sv translation
languagede

Verbindungsabbrüche und fehlgeschlagene Mobilteilübergaben (Handover) sind typische Symptome einer DECT Multizelle mit schwachen RSSI-Werten der DECT-Synchronisationsquellen.

Um dies zu beheben, melden Sie sich in der Web-Benutzeroberfläche jeder Basisstation der Multizelle an und werfen Sie einen Blick auf die DECT-Kette und die Basisstationsgruppe. Überprüfen Sie die Werte der DECT-Synchronisationsquelle RSSI.

Stellen Sie sicher, dass die "DECT-Synchronisationsquelle" jeder Basisstation einen RSSI-Wert von mindestens -75dBm hat. Schwächere RSSI-Werte (z.B. -76dBm oder weniger) können zu Verbindungsabbrüchen und fehlerhaften Handover führen.