The M700/M900 DECT base station can be used as a single cell or as a multi cell system. To configure the M700/M900 as a multicell, a base station with access data is registered on the respective PBX (here an example on the 3CX) and this is switched to Multicell "Enabled". Thus, this base automatically becomes the primary base and every further base becomes a secondary base of the same network after switching on the Multicell mode, as long as you have used the same "System Chain ID". How the configuration works in detail can be seen in the following description.
Activating the multi-cell mode |
Warning |
---|
ATTENTION: Before you set up another base, the first, primary base must be completely set up. This will then show "Allowed to Join as Primary" at the end. |
First you enter the IP address of the first M700/M900 base station in your web browser and
use the default credentials for "username" and "password": adminInfo How to find the IP address of your base is described in the following article: How to enter M300, M700, M900 - Web Interface
- First navigate to the "Multi cell" menu item. Now it looks like this:
Please switch the item "Multi cell system" to "Enabled".
Info Please note the "System Chain ID". This must be identical for all devices in the same cell. After you have accepted this setting, the view of the start page changes as follows after a short time:
" Multi cell Unchained - Allowed to Join as Primary "
Now you have prepared everything for the multicell and you can add more bases that report as secondary bases.
Info Once you have added a second, (Secondary) Base, the Multicell is created and the Primary Base shows the following:
"Multi cell Ready (Active) Primary"- Now start a second M700/M900 and open its web interface.
- Navigate again to the menu item "Multi cell".
- Set the setting for "Multi cell system" to "Enabled" and accept the setting.
Note that the "System Chain ID" is identical to the Master Base. By default it is set to "512". - After a short time the display of the sersten secondary base changes as follows:
And after a few moments, when the first secondary base has synchronized with the primary base, the view changes again:
For other secondary bases, synchronization may vary depending on the size of the multicell.
→ If you want to add more bases to your multicell, proceed in the same way as adding the second base station.
Include Page Howto Footer - en Howto Footer - en
...
German | |||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Die M700/M900 DECT Basisstation lässt sich sowohl Einzeln als auch Verbund verwenden als Multizelle. Um die M700/M900 als Multizelle zu konfigurieren, wird eine Basisstation mit Zugangsdaten an der jeweiligen PBX angemeldet (Hier ein Beispiel an der 3CX) und diese wird auf Multicell "Enabled" geschaltet. Damit wird diese Basis automatisch zur Primären Basis und jede weitere Basis wird nach dem einschalten des Multizellen Modus zu einer sekundären Basis des selben Verbundes, immer vorausgesetzt sie haben die gleiche "System Chain ID" verwendet. Wie die Konfiguration im Detail funktioniert sehen sie in der folgenden Beschreibung.
Aktivieren des Multizellen Modus
→ Wenn sie weitere Basen zu Ihrer Multizelle hinzufügen wollen, verfahren sie auf die gleiche Weise wie beim Hinzufügen der zweiten Basisstation.
|
...