Servicing → System Logs → Syslog → Log Level
M200Configuration → System Logs → Syslog → Log Level

Phone User Interface

N/A

Text Configuration

log.syslog_level = VALIDVALUE

XML Configuration (C520, C620, M100, M200 only)

<log>

<syslog_level>VALIDVALUE</syslog_level>

</log>

Description

Sets the log level. The higher the level, the larger the debug output.

ModelLog level
C520
C620
M100
M500 (at 1.09.02 only)
5 - all
4 - debug
3 - info
2 - warning
1 - error
0 - critical
M500 (starting with 1.11.0 and later)7 - debug
6 - informational
5 - notice
4 - warning
3 - error
2 - critical
1 - alert
0 - emergency

Valid Values

ModelValid Values
C520
C620
M100
M500 (at 1.09.02 only)
0-5
M500 (starting with 1.11.0 and later)0-7

Default Value

ModelDefault Value
C520
C620
M100
M500 (at 1.09.02 only)
2