Content
C520Â C620Â M100Â M200 M500
Web User Interface
Model | Web User Interface |
---|---|
C520 C620 M100 M500 | Servicing → Provisioning → Resynchronization → Schedule Check → Radio button options (Disable, Interval, Days of the Week) |
M200 | Configuration → Provisioning → Resynchronization → Schedule Check → Radio button options (Disable, Interval, Days of the Week) |
Phone User Interface
N/A
Text Configuration
provisioning.schedule_mode = VALIDVALUE
XML Configuration (C520, C620, M100, M200 only)
<provisioning>
<schedule_mode>VALIDVALUE</schedule_mode>
</provisioning>
Description
Sets the type of schedule check for configuration and firmware files.
If set to "weekday", you must also configure the settings provisioning.weekdays, provisioning.weekdays_start_hr, and provisioning.weekdays_end_hr.
M500 Multi-cell: Configure this setting for a specific base station. This is NOT a site-wide setting.
Valid Values
disable, interval, weekday
Default Value
Model | Default Value |
---|---|
C520 | interval |