XML Configuration

<recording_mechanism perm="PERMISSIONFLAGS">VALIDVALUE</recording_mechanism>

Description

Controls how to record calls, these keywords are allowed:

 SIP      -> sends sip INFO with "Record: on" or "Record: off"
 DTMF4242 -> sends DTMF-sequence, the same one for starting and stopping - please substitute 4242 with the sequence you need in your environment.
 NONE     -> no recording at all, on 820, 821 and 760 this means that the soft key for recording wont be shown, on 870 this key will be disabled
 '''added with firmware versions 8.7.3.19 and 8.7.4.6:'''
 SIP_CALL:42@pbx.com
          -> make a conference by calling the configured SIP-URI. Behind this URI should be a recorder that auto-answers all calls 
             and that records them

Valid Values

keyword, see description

Default Value

SIP