Content
D-SERIES
Web User Interface
Advanced - Network (Tab) - HTTP(Section): Webserver connection type
Phone User Interface
- V8 / V10: Press "Settings" - Network - Webserver - Webserver Type
- Snom300: Navigation Key Down - Web Interface
- Snom320: Navigation Key right or press "Settings" - Web Interface
- Snom360/370: Press "Settings" - Network
- Snom820/870: Press "Menu" - Network - Webserver
Firmware
N/A
XML Configuration
<webserver_type perm="PERMISSIONFLAGS">VALIDVALUE</webserver_type>
Description
For D8XX series:
- If the setting is set to https or http_https the new web UI will be available via https on port 443.
- If the setting is set to http or http_https the old web UI will available via http on the port set in setting 'http_port'
- If the setting is set to off no web UI will be available
Set up the type of connection the phone’s web server is willing to answer to.
Press the menu key, use the navigation key to go to the submenu “Webinterface”, and select “Server”. Then change the type of connection to one of the other types.
Valid Values
- http
- https
- http_https
- off
Default Value
D1xx, D3xx and D7xx: http_https
D8xx: https (starting from 10.1.159.12)