Content

Page tree

C520 C620 M100 M200 M500

Web User Interface

ModelWeb User Interface
C520
C620
M100
M500

Servicing → Provisioning → Resynchronization → Schedule Check → Radio button options (Disable, Interval, Days of the Week)

M200

Configuration → Provisioning → Resynchronization → Schedule Check → Radio button options (Disable, Interval, Days of the Week)

Phone User Interface

N/A

Text Configuration

provisioning.schedule_mode = VALIDVALUE

XML Configuration (C520, C620, M100, M200 only)

<provisioning>

<schedule_mode>VALIDVALUE</schedule_mode>

</provisioning>

Description

Sets the type of schedule check for configuration and firmware files.

If set to "weekday", you must also configure the settings provisioning.weekdays, provisioning.weekdays_start_hr, and provisioning.weekdays_end_hr.

M500 Multi-cell: Configure this setting for a specific base station. This is NOT a site-wide setting.

Valid Values

disable, interval, weekday

Default Value

ModelDefault Value
C520interval
C620
M100
M200
M500
disable