Content

Page tree

D-SERIES

Web User Interface 

D1xx, D3xx, D7xx, D81x: Advanced - Network (Tab) - HTTP(Section): Webserver connection type

D86x: N/A

Phone User Interface

For D1xx, D3xx, D7xx, D81x:

Press Settings - Network - Webserver - Webserver Type

For D86X:

Press Settings - System - Advanced - Webserver

Firmware

https (D86x): from 10.1.159.12 onwards

XML Configuration

<webserver_type perm="PERMISSIONFLAGS">VALIDVALUE</webserver_type>

Description

This setting determines the protocol that the phone's web server should use for further communication.

For D86X:

  • If the setting is set to https or http_https the Phone Manager (web UI) can be accessed using HTTPS protocol on port 443.
  • If the setting is set to http or http_https the legacy web UI can be accessed using HTTP protocol only on port 3112.
  • Warning: If the setting is set to off no Phone Manger or legacy web UI can be accessed anymore.

For D1xx, D3xx, D7xx, D81x:

  • If the setting is set to https or http_https the web UI will be available via https on port 443.
  • If the setting is set to http or http_https the web UI will be available via http on port given in http_port.
  • Warning: If the setting is set to off no web UI will be available.

Using HTTP significantly reduces security, as every username and password is transmitted unencrypted between browser and phone. Snom recommends using HTTPS only!


Note: Activation of changes requires a reboot.

Valid Values

  • http
  • https
  • http_https
  • off

Default Value

D1xx, D3xx, D7xx, and D81x: http_https

D86x: https