DECT M-Series Firmware
Index:
Bases and Handsets
Release Notes
BS650B02 HS650B02 Release - 15.10.2022
Delta to V610B5
V650B2 for base stations, handsets.
- no M5 repeater support, M6 available end of 2022
- Use latest release V9B1 for M9B Beacon Gateways
- Use latest release V530B2 for A190 multi-cell headsets
Features added:
- zero touch cloud support
- handover abort, ressources exceeded fix
- Dect XML Minibrowser (http(s))
- OPUS support with optional extension board
Bugfixes:
- DECT-905 Full name on handset display
DECT-1024 M400, M900: can't receive check-sync behind cloud
DECT-1062 Broadsoft: M900 search functionality is looking for the exact match
BS610B05 HS610B05 Release - 25 July 2022
Delta to V530B7
V610B5 for base stations, handsets.
- no M5 repeater support
- Use latest release V9B1 for M9B Beacon Gateways
- Use latest release V530B2 for A190 multi-cell headsets
Features added:
- M400 base and M30 handset support
- improvements TLS stack
- extended alarm messaging protocol
- extended alarm and real time location handling
- Group Push 2 Talk
- Dect XML Minibrowser (http)
- E911 emergency profile handling
- user, engineer, admin user profiles
Bugfixes:
DECT-950 Change Italian translation on the WUI
DECT-994 "Transfer this call to the held call?" is not translated
DECT-1011 SSL handshake fails on MX00
- DECT-1022 M900: 530.7 Unexpected reboots Error:05
BS530B10 HS530B10 Release - 23.02.2023
Delta to V530B7
V530B10 for base stations, handsets.
- Repeater needs to be upgraded to V530B2 to avoid incompatibilities.
- Use latest release V9B1 for M9B Beacon Gateways
- Use latest release V530B2 for A190 multi-cell headsets
Features added:
Bugfixes:
- DECT-xxx several fixes for error 4, 41, 43, 50
BS530B07 HS530B07 Release - 13 May 2022
Delta to V530B2
V530B7 for base stations, handsets.
- Repeater needs to be upgraded to V530B2 to avoid incompatibilities.
- Use latest release V9B1 for M9B Beacon Gateways
- Use latest release V530B2 for A190 multi-cell headsets
Features added:
- stability release
- improvements in alarm-, LDAPS- and TLS-handling
Bugfixes:
- DECT-924 No incoming call on 520B1/530B1
- DECT-929 Base station sometimes cannot reach LDAP server
- DECT-933 M900: Unexpected Reboot (Error:92)
- DECT-960 Alarmmessages are no longer accepted by Base
- DECT-988 M900: 530.2 Unexpected reboots Error:71
- DECT-999 M900 looses SIP registration to Cloud PBX
- DECT-1005 M300 can't establish connection with server
- DECT-1006 Firmware path is not correctly set
- DECT-938 M300 goes to reboot loop with debug feature enabled
- DECT-965 Cannot configure two alarm types to M85 handset
- DECT-980 TLS Register after reboot doesn't work if > one account per base
- DECT-1022 M900: 530.7 Unexpected reboots Error:05
- DECT-627 Snom M85 - Profiles 1 - 7 don't work once changed
- DECT-931 Snom (DECT-773) RTX8200 - HS and BS settings are not synced
- DECT-982 Alarm profiles cannot be selected via Web Guides
BS530B02 HS530B02 Release - 23 June 2021
Delta to V520B1
V530B2 for base stations, handsets, headsets and repeater.
Features added:- DECT-809 Add provisioning timer (M700, M900)
- DECT-784 PTT for A190
- DECT-793 Force password change to comply with Cybersecurity Bill in California (M900)
- Provisioned with default passwords (Multi-cell)
Log in will ONLY cause a prompt to change default passwords when attempting access to the synchronization primary
base. Attempts to log-in on any other base in the chain with default credentials will be denied until at least one of the passwords are changed through the provisioned configuration file or through the synchronization primary base.
- DECT-915 TLS v1.2 support with two new Cipher Suites (M300):
- TLS_ECDHE_RSA_WITH_AES_128_CBC_SHA
- TLS_ECDHE_RSA_WITH_AES_128_CBC_SHA256
- Supported Cipher Suites as server are:
- TLS_RSA_WITH_AES_256_CBC_SHA256
- TLS_RSA_WITH_AES_128_CBC_SHA256
- TLS_RSA_WITH_AES_128_CBC_SHA
- TLS_RSA_WITH_AES_256_CBC_SHA
Bugfixes:
- DECT-866 XSI CallLogs did not work properly
- DECT-654 Alarm key did not trigger alarm
- DECT-857 Export and import of settings led to SIP registration error
- DECT-871 Spelling error in LDAP sort menu
- DECT-874 Base crashes after SIP notify
- DECT-933 Fixed some causes for Unexpected Reboot 92 Error
- DECT-686 Fixed some causes for Unexpected Reboot 59 Error
- DECT-xxx Fixed SIP reg error with TLS
- DECT-879 Fixed wrong Russian translations
- DECT-904 Registration failed with "Client initiated Connections" (RFC5626) set to on
- DECT-910 Setting "Client initiated Connections" was not correctly synchronized
- DECT-922 Setting "allow_call_groups" is no longer available on base stations that not support it (M700 and M900)
- DECT-548 colon ":" can now be included in the firmware URL to specify a port
- DECT-927 System was unusable after FW upgrade to V520B1, in connection with DECT-910
Known Issues:
- DECT-959 Polish language cannot be set through provisioning
BS520B01 HS520B01 Release - 18 January 2021
Delta to V510B1/2V520B1 for base stations, handsets, headsets and repeater.
Features added:
- DECT-753 Option to enable/disable semi-attended transfer
- DECT-655 Support for callback number in alarm message
- DECT-719 Configurable Headset buttons for Speed-dial (A190)
- DECT-778 STUN server for FQDN can now contain 63 characters
- DECT-XXX Increase maximum of displayable characters for caller ID on M70, M80, M85 and M90
- DECT-XXX Bluetooth 4.2 support on M70, M80, M85 and M90
Bugfixes:
- DECT-542 Network_sync_debug_enable can correctly set via provisioning
- DECT-808 NAT issues with cloud PBX
- DECT-775 Audio problems due to resource issues with STUN
- DECT-686 Fixed two potential causes of Unexpected Reboot Error 59 (one in connection with XSI get)
- DECT-845 Export of local phonebook caused duplicate entries
- DECT-856 PnP was not working
- DECT-XXX Bad audio with M700 and M25
- DECT-XXX Fixed memory leak in DNS failvoer
- DECT-XXX Daylight saving time changed at the wrong date/time
- DECT-XXX Bad invite had handsets ring, even if cancelled
- DECT-XXX Transferred call dropped after 30 seconds
- DECT-XXX SIP extension part of user login not synced in multicell
- DECT-XXX Add new extension always added as idx 1 and not new entry
- DECT-XXX Pressing sidekey when handset in idle to minimum sound volume causes volume icon to disappear
- DECT-XXX Retrieved call is rejected with “Not acceptable here” when set on hold
- DECT-XXX PBX SIP registration expiry ignored by base station
- DECT-XXX Paired terminal: cannot end call when making conference
- DECT-XXX Handset still displays Conference screen after hanging up one party
- DECT-681 Race condition was fixed that could lead to Unexpected Reboot Error 92
- Simple XML Minibrowser does not handle softkey in XML properly
- Simple XML Minibrowser invalid combination when attempting to remove extensions from URL string
BS510B02 HSV510B02 Release 31 March 2021
Delta to V510B1
- Base Station releases V510B1should be used with Repeater releases V480B5 or later.
- Headset Version is V500B1.
- A190 might require an update of the voice prompts which can be done through dect.snom.com as shown on the picture below.
-
Bug fixes:
- DECT-847 - Handsets not ringing - Follow PBX expiry response
- DECT-874 - Base station crashes after SIP notify
- DECT-686 - M700 / M900: Unexpected reboots Error:59
- DECT-808 - NAT Issues with 3CX and STUN CONFIGURATION
- DECT-858 - VF_DE / BSFT: SIP REGISTER failing after transport protocol is switched unintentionally
- DECT-871 - Spelling error in LDAP "Sort" choice Menu
- DECT-857 - Export Settings and Uploading them to the base again leads to sip rgistration issue
- DECT-626 - "SIP extension part of user login:" not synced in multicell
- DECT-654 - Alarm key does not trigger alarm
- DECT-853 - M9B: Menu BTLE Config, the M9Bs cannot be found..
- DECT-856 - PnP Provisioning not working anymore in FW 510
BS510B01 HS510B01 Release - 25 September 2020
Delta to V501B1/B2
- Base Station releases V510B1should be used with Repeater releases V480B5 or later.
- Headset Version is V500B1.
- A190 might require an update of the voice prompts which can be done through dect.snom.com as shown on the picture below.
-
Features added:
Bug fixes:
- DECT-810 - Transferred call drops after 30 seconds
- DECT-700 - Directory full name cut on display (M70, M80, M90)
- DECT-782 - Resolved Non-Compliance RFC 3261 Clause 17.2.2 Non-INVITE Server
- DECT-785 - pp_menu_hide parameters not updated
- DECT-681 - Unexpected Reboots Error:92
- DECT-XXX - Wired headset could cause handset to reboot
- DECT-XXX - Handset issues LDAP connection failed though connection was ok
- DECT-XXX - DNS failover memory leak was fixed
BS501B01 HS501B02 Release - 01 September 2020
Delta to V500B1- Base Station releases V501B1should be used with Repeater releases V480B5 or newer.
- Release version for base stations is V501B1, Handset version is V501B2
Features added:
- DECT-623 LLDP-MED is set to "enabled" on default
- DECT-467 Add OPUS support to M900 (needs A900 DSP module)
Bug fixes:
- DECT-708 call is not forwarded when "Diversion Inhibited" is enabled with Broadsoft
- DECT-704 can hold call when session timer is enabled with Broadsoft
- DECT-628 M85 does not trigger "No movement alarm" when put in charging cradle
Known issues:
- BV32 codec with handover not working
BS500B01 HS500B01 Release - Juli 2020
Delta to V450B13 Features added:
- DECT-688 Noise Cancelling option (M85), Noise reduction option on (M70, M80, M90)
- DECT-665 LLDP-MED can be set through provisioning
- DECT-685 TLS outbound support (Explicit Routing)
- DECT-559 Longer XSI credentials
- DECT-662 Slovak language for Handsets
- DECT-605 Czech language for Handsets
- DECT-459 Push-to-talk (PTT) on Handsets (reduces the number of parallel calls by 2(for NB codecs) or 1(for WB codecs) per base if activated)
- DECT-669 Increased provisioning file size (M300: 700KB, M700: 700KB, M900: 1MB)
- DECT-337/DECT-650 MOH server with TLS
Bug fixes:
- DECT-696/DECT-697 Issues with Spanish and Russian language resolved
- DECT-654 Alarm key did not trigger alarm when delay was configured
- DECT-549/DECT-578 Phone directory does not modify numbers anymore with starting "+" when provisioning is used
- DECT-664 LAN synchronization could not be configured using provisioning (M900)
- DECT-703 Context key was non-functional during transfer
- DECT-637 Certain server requests were sent in a loop (M300)
- DECT-646 In certain situations there was static noise on incoming calls
- DECT-684 XSI server was not correctly synchronized in Multi-cell set-up
- DECT-681 Unexpected Reboot 92
- DECT-799 Backlight flickering when message LED is active
BS450B13 HS450B13 Release - December 2019
Bugfixes:
New features:
Known issues:
DECT-684 No synchronization on the xsi_server values @M700
DECT-646 DECT: Static noise with incoming call
- DECT-686 Unexpected reboots Error:59
DECT-681 Unexpected Reboots (Error 92) @M900
- DECT-696 Handsets: Russian translation of menu / info messages uses wrong charset
- DECT-697 Handsets: Spanish info message ambiguous
BS450B11 HS450B11 Release - September 2019
Bugfixes:
DECT-640 - FIX: M700, M900: Remove dash sign from called numbers
DECT-647 - FIX: M700, M900: Broadsoft XSI wrong downloaded URL (XSI directories and Call Logs)
DECT-625 - FIX: M700: Fixed reboot during handsets fw upgrade
DECT-639 - FIX: M700, M900: XSI and LDAP addressbook cannot be activated without manual intervention from web UI
- DECT-632 - FIX: M700, M900: Wrong SIP request URI in Record-Route (strict routing) scenario
- DECT-629 - FIX: M700, M900: No audio after hold INVITE or reINVITE
- DECT-641 - FIX: M700, M900: Broadsoft XSI Caller-ID blocking: SIP authentication not working
- DECT-615 - NEW: LDAP number lookup can be disabled through provisioning
BS450B08 HS450B05 Release Candidate - April 2019
Bugfixes:
DECT-614 - FIX: M700: Fixed unexpected reboots and stability issues
DECT-625 - FIX: M700: Fixed reboot during handsets fw upgrade
DECT-617 - FIX: Provisioning using file inclusiong (XML tags <setting-files><file>) is not working
DECT-504 - FIX: No audio after call from group with music (RTP collision)
Known Issues:
- DECT-629: No audio after hold INVITE or reINVITE
- DECT-632: Wrong SIP request URI in Record-Route (strict routing) scenario
- DECT-639: XSI and LDAP addressbook cannot be activated without manual intervention from web UI
BS450B07 HS450B05 - Not Released
Bugfixes:
- DECT-612 - FIX: Downloaded tbook format address book no longer work
- DECT-607 - FIX: Certificates not used on M300/M700 with device out of the box 410B4
- DECT-571 - FIX: SRTP: No audio after reINVITE
- None - FIX: Central Dir not changed when using provisioning file
BS450B06 HS450B05 - Not Released
Bugfixes:
- DECT-594 - FIX: M700 does not send Session-Refresh reINVITE
BS450B05 HS450B05 - Not Released
Known Issues:
- None: Hide number sub menu not sync
New Features:
- None - NEW: HS menu control via provisioning
- DECT-528 - NEW:: Support alarm time-out configurable in seconds
- DECT-527 - NEW: Support different alarm tones/audibles
- DECT-489 - NEW: Make XSI addressbook type provisionable @broadsoft
- DECT-488 - NEW: Make XSI username and password provisionable @broadsoft
- DECT–487 - NEW: Enable sip name as user name for LDAP feature
- DECT-460 - NEW: Support of LDAP over TLS
- DECT-287 - NEW: Expanding SIP Alert-Info Header Supports
- None - NEW: Comfort Noise packets support
- None - NEW: DECT tree save / recover button on the webpage
- DECT-568 - NEW: Make XSI Caller-ID blocking provisionable @broadsoft
Bugfixes:
- DECT-511 - FIX: Improved primary failover alogorithm
- DECT-431 - FIX: SRTP: auth_tag_length has no valid setting value
- DECT-367 - FIX: XSI Sip Authentication does not work with different xsi username @broadsoft
- DECT-601 - FIX: Ethernet frames bigger than 1514 bytes are discarded in VLAN tagged scenario
- DECT-571: SRTP: No audio after Seq goes from 65535 to 0 and reINVITE
- DECT-569 - FIX: Timezone and dst settings are missing from the XML configuration
- DECT-565 - FIX: No audio after call transfer with codec change
- DECT-564 - FIX: SRTP: DECT does not play SRTP audio after a while
- DECT-563 - FIX: Hold/un-hold via hold and talk SIP events ends with a no audio
- DECT-562 - FIX: Codec re-negotation ends in no audio
- DECT-551 - FIX: Crash when deleting device identity certificates
- DECT-550 - FIX: M700 does not send ACK if 200 OK contains Record-Route
- DECT-543 - FIX: Security section of web GUI gets messed up when uploading client certificate X509v3 with key length of 4096
- DECT-540 - FIX: M300 crashes when uploading client certificate
- DECT-532 - FIX: Provisioning: RTP ports cannot be changed
- DECT-509 - FIX: using \\ characters into firmware settings broke the firmware menu
- DECT-481 - FIX: Alarm not working after Declined call
- DECT-461 - FIX: Handset's directory Search returns only mobile number
- DECT-384 - FIX: M700 reboots when place calls on hold with g729 and SRTP - SRTP Auth enabled
- DECT-277 - FIX: Wrong user_srtp value
BS440B03 HS440B03 - Not Released
New Features:
- DECT-544 - NEW: Support for TLS 1.2
- None - NEW: M25 messaging support
- DECT-521 - NEW: Hide number via XSI @broadsoft
Bugfixes:
- DECT-495 - FIX: Unable to pair Konftel 300Wx handset
- DECT-501 - FIX: Device does not update the Session-Expire header in case of 422 SIP error
- DECT-497 - FIX: Support XSI SIP Authentication for Address book @broadsoft
- DECT-456 - FIX: SIP stack cannot handle dual RTP media description
- DECT-403 - FIX: Wrong ringing tone with Ireland country
BS420B01 HS420B07 - Not Released
New Features:
- DECT-464 - NEW: Feature Request uaCSTA SIP Support
Bugfixes:
- DECT-473 - FIX: M700 does not allow to provision Spanish Language
- DECT-469 - FIX: Central Directory removed from all the handsets and isn't recovered
BS410B14 HS410B11 - Released
Known Issues:
- None: Hide number sub menu not sync
Bugfixes:
- None - FIX: Configuration download during boot will not be shared
BS410B13 HS410B11 - Not Released
Known Issues:
- None: Hide number sub menu not sync
Bugfixes:
- None - FIX: RSSI value from a good value (-6xdBm) to -Infinity
- None - FIX: Power toggle with enabled Call Forwarding may result in double SIP registration.
- None - FIX: Handle Connection Lost from central base station
BS410B11 HS410B11 - Not Released
Known Issues:
- None: Hide number sub menu not sync
New Features:
- None - NEW: Backoff mechanism for provisioning.snom.com
- None - NEW: Remote removal of handset / use of device configured
Bugfixes:
- None - FIX: resets at "Forced reboot" cmd - error 41
- DECT-557 - FIX: XSI client: malformed communication
- None - FIX: Importing Germain chars to handset
- None - FIX: Unexpected reboot cause 5
BS410B10 HS410B07 - Not Released
Known Issues:
- None: Hide number sub menu not sync
Bugfixes:
- DECT-431- FIX: SRTP: auth_tag_length has no valid setting value
- DECT-277 - FIX: Wrong user_srtp value
- None - FIX: Issues with base reboot with Error 41
- None - FIX: Improved multicell stability
- None - FIX: Improved muilticell error logging and reporting
BS410B09 HS410B07 - Not Released
Known Issues:
- None: Hide number sub menu not sync
New Features:
- DECT-541 - NEW: M300/M700 does not support RFC 2617 (qop)
BS410B07 HS410B07 - Not Released
Known Issues:
- None: Hide number sub menu not sync
New Features:
- DECT-521 - NEW: Hide number via XSI
BS410B06 HS410B06 - Not Released
Bugfixes:
- DECT-522 - FIX: M25 Conf. key not shown on V410B3
New Features:
- None: - NEW: Hide number setting
BS410B04 HS410B3 - March 2018
Bugfixes:
- DECT-486 - FIX: Using SRTP can cause DECT base crash
- DECT-477 - FIX: Configuring the VLAN priority breaks the multi cell communication
- DECT-484 - FIX: Missing REFER in transfer scenario
- None: The handset stores only a few text Messages
- None: The handset shows only the name name, doesn't show the number of caller/callee
Repeater
Release Notes
M5 - 480B05 Release - 07 Oktober 2020
New features:
- Repeater chaining is now supported
M5 - RPV39
New Features:
- Support for repeater statistics
- Repeater syslog status improved
- Improved busy handling
-
Page:
-
Page:
-
Page:
-
Page:
-
Page:
-
Page:
-
Page:
-
Page:
-
Page:
-
Page:
-
Page: